AFLOWT EM470 Slurry Electromagnetic Flow Meter

Array
(
)
Back to catalog

AFLOWT EM470 Slurry Electromagnetic Flow Meter

Slurry Electromagnetic Flow Meter

Noise is common in process fluids containing solid particulates, and it can influence the measurement. Slurry magnetic flow meter AFLOWT EM470 adopts square wave excitation and 25Hz/30Hz high excitation, which can eliminate interfacerence between the sharp wave noise generated by solid particles, ensures accurate measurement of viscous medium.

Features

Industries

Cement slurry, sludge, gypsum slurry, paper pulp, juice, syrup, ore slurry, coal slurry, etc.


Technical Specification

Size DN3-DN3000mm (1/8"-120 )
Accuracy ±0.5% of reading at flow velocity ≥ 0.5m/s
Velocity 0.1~15 m/s
Repeatability ≤0.17%
Excitation current 125 mA, 187 mA, 250 mA
Excitation Frequency 25 Hz/30 Hz
Structure Compact / remote, cable length 10m standard, 100m max
Conductivity > 5 μS/cm, demineralized water > 20 μS/cm
Protection Grade Transmitter: IP65 standard, IP67 optional
Sensor: IP65 standard, IP68 (submersible, only available for remote type)
Electrode SS316L, Hastelloy C, Hastelloy B, Titanium,Tantalum, Platinum-iridium
Power Supply 85~250 VAC (50/60 Hz), 20~36 VDC
Power Consumption <20W
Signal Output Analog 4~20mA (load resistor 0~750Ω)
Frequency Forward & reverse flow output with a frequency range of 1~5000Hz
Alarm Two isolated open collector transistor (OCT) outputs for alarm signals
Communication RS485 MODBUS RTU standard, HART, GPRS, PROFIBUS optional
Display LCD Display,128X128mm, three lines, 4 buttons
Ambient Temperature -20°C~60°C
Fluid Temperature Compact: -20°C~80°C, Remote: -20°C~120°C
Liner Material PTFE (-20℃~150℃, DN15-DN1600)
FEP (-20℃~120℃, DN15-DN1800)
PFA (-20℃~160℃, DN15-DN800)
Polyurethane (-10℃~60℃, DN40-DN1600)
Neoprene (-10℃~80℃, DN40-DN3000)
Hard Rubber (-10℃~80℃, DN 40-DN3000)
Ceramic (-20℃~180℃, DN15-DN200)
Sensor Material Measuring tube: SS304
Flange & housing: carbon steel (standard), SS304 / SS316 optional
Transmitter Material Aluminium alloy with epoxy painting
Nominal Pressure Flange PN10 / PN16 / PN25 / PN40 DIN
10K / 20K / 30 K JIS
150# / 300# / 600# ANSI
Insertion, tri-clamp wafer, thread PN16
Display Instantaneous flow, total flow, flow velocity
Function High and low alarm, empty pipe alarm, exciting alarm,self-diagnosis
Totalizer Three built-in totalizers: forward flow, reverse flow and net flow
Display Unit L/s, L/m, L/h, m3/s, m3/m, m3/h, UKG, USG, gal/s, gal/m, gal/h, kg/s, kg/m, kg/h, t/s, t/m, t/h
Language English, Chinese