Applications in the chemicals and petrochemicals industries, for example, in power generation and heat-supply systems involve widely differing fluids:
Measured Medium | Liquid, Gas, Steam | |
Medium Temp. | -40~+250℃; -40~+350℃ (high temperature type) | |
Pressure | Flange |
DIN PN10/PN16/PN25/PN40 JIS10K/20K/30K/40K ANSI 150#/300# |
Wafer | 4.0MPa | |
Thread | 1.6MPa | |
Tri-clamp | 1.6MPa | |
Insertion | 1.6MPa | |
Accuracy |
±1.0% (Flange/Wafer/Thread/Tri-clamp) ±1.5% (Insertion type) |
|
Flow Range |
Liquid:0.4-7.0m/s; Gas:4.0-60.0m/s; Steam:5.0-70.0m/ |
|
Specifications |
DN15-DN300 (flange/wafer type) DN80-DN2000 (insertion type) DN15-DN100 (thread/sanitary type) |
|
Body Material |
SS304 (standard) SS316 (optional) |
|
Reynolds Number | Normal 2x10⁴~7x10⁶ | |
Resistance Coefficient | Cd≦2.6 | |
Vibration Acceleration Allowed | ≦0.2g | |
IEP ATEX | II IG Ex ia IIC T5 Ga | |
Ambient Condition | Ambient Temp. |
-40℃~65℃ (Non ex-proof site) -20 ~55 (Ex-proof site) |
Relative Humidity | ≦85% | |
Pressure | 86-106kPa | |
Power Supply | DC12-30V or 3.6V lithium battery powered | |
Signal Output | 4-20mA, Pulse | |
Communication | RS485 Modbus or HART |