Advantages
Parameter | Value |
---|---|
Nominal diameter of the pipeline, DN | wetted PEA: 10 ÷ 5000 clamp-on PEA: 50 ÷ 5000 |
Accuracy, %, with flowrate range from 1:100, single-beam sounding | ± 2 |
Accuracy, %, with flowrate range from 1:100, two-beam sounding | ± 1 |
Accuracy, %, with flowrate range from 1:100, four-beam sounding | ± 0,5 |
Flow velocity range, m/s | 0.1 ÷ 20 |
Fluid temperature range, °С | wetted PEA: minus 30 ÷ 160 clamp-on PEA: minus 30 ÷ 150 |
Ambient temperature for transmitter, °С | 0 ÷ 50 |
Maximum pipeline pressure*, MPa/bar | wetted PEA: 2.5/25 clamp-on PEA: — *- on request is possible to supply pipeline sections with wetted PEAs designed for up to 25 MPa/250 bar pressure. |
Transmitter / transducers protection | IP54/IP68 |
Measurement data logging, number of records, hourly log | 1440 |
Measurement data logging, number of records, daily log | 60 |
Measurement data logging, number of records, monthly log | 48 |
Measurement data logging, number of records, programmable | 14 400 |
Measurement data logging, number of records, batching | 512 |
Power supply, VDC | 24 |
Power consumption, VA | under 12 |
Transmitter weight, kg | under 3 |
Transmitter dimensions, mm | 250 ÷ 132 ÷ 90 |